10 exam-style questions with answers and explanations, straight from our 1,050-question bank. Tap an answer to check yourself. When you're ready, take the scored version in the free practice test.
The CTS-I exam has 110 questions and runs 2 hours 30 minutes.
These 10 free CTS-I questions are organized by exam domain, so you can see how each part of the Certified Technology Specialist - Installation (CTS-I) blueprint is tested. Reveal the answer and explanation under each question.
Domain 1: Implement Pre-Installation Activities 17% of exam
Question 1
During pre-installation review, an installer finds that the AV signal flow diagram calls for a 98-inch display, while the architect's interior elevation shows a 75-inch display at the same wall location. The mounting substructure has already been installed by the general contractor. What should the installer do FIRST?
Show answer & explanation
Correct answer: B - Submit a Request for Information (RFI) to obtain a documented resolution before proceeding
Question 2
An installer needs to verify the exact location of ceiling-mounted loudspeakers relative to HVAC diffusers, sprinkler heads, and lighting fixtures before rough-in. Which drawing provides this information MOST directly?
Show answer & explanation
Correct answer: A - The reflected ceiling plan
Question 3
Equipment is delivered to the jobsite. As the installer unpacks a power amplifier, they notice a dented chassis corner, though the unit powers on and passes a basic signal test. What is the MOST appropriate action?
Show answer & explanation
Correct answer: A - Document the damage with photographs and report it per the project's damage-claim process
Domain 2: Practice Ongoing Project Responsibilities 12% of exam
Question 4
Midway through installation, the client's facilities manager stops by and asks the lead installer to add two extra ceiling speakers in an adjacent corridor, saying it will 'only take an hour.' The speakers are not shown in the contract documents. What should the installer do?
Show answer & explanation
Correct answer: D - Direct the request through the project manager so it can be processed as a change order
Question 5
An installer arrives to find that the electrical contractor has run 120 VAC branch circuit conductors through the same cable tray designated on the AV drawings for balanced audio and control cabling. What is the PRIMARY technical concern the installer should raise?
Show answer & explanation
Correct answer: D - Induced electromagnetic interference degrading the audio and control signal quality
Domain 3: Conduct Site Rough-In/First-Fix 12% of exam
Question 6
An installer is pulling Cat6a UTP through a long conduit run with several bends. The pull becomes difficult, so a helper wraps the cable around their hands and pulls harder to free it. Per ANSI/TIA-568 installation requirements, what is the MAXIMUM pulling tension permitted on a four-pair UTP cable?
Show answer & explanation
Correct answer: B - 25 lbf
Question 7
A ceiling cavity above a suspended ceiling is used by the building's HVAC system as a return-air path. Which cable rating is required for AV communications cable run freely (not in conduit) through this space?
Show answer & explanation
Correct answer: A - CMP (plenum)
Question 8
While dressing cable into a J-hook, an installer bends a Cat6 U/UTP cable with a 0.25 in outer diameter around a sharp 90-degree corner with a radius of roughly 0.5 in. What is the MOST likely consequence?
Show answer & explanation
Correct answer: B - The bend violates the minimum bend radius, degrading NEXT and return loss performance
Domain 4: Install AV Systems 39% of exam
Question 9
An 84 lb flat panel display will be installed on a wall mount weighing 26 lb. Project documentation requires a 5:1 safety factor for the supporting structure. What MINIMUM load capacity must the substructure be rated to support?
Show answer & explanation
Correct answer: C - 550 lb
Question 10
A 70 V distributed loudspeaker system has 12 ceiling loudspeakers tapped at 8 W and 4 pendant loudspeakers tapped at 16 W. Following common practice of limiting the summed taps to 80% of amplifier rated power, what is the MINIMUM amplifier power rating required?